IEPE signal conditioner YE3826A

Quick Overview

The YE3826A is an IEPE signal conditioner

Product specifications include: ±10V | Gain 1,10 (switchable) | 0.3Hz to 102kHz | 0°C to +40°C | 12 channels | 19″ case | Monitors normal or faulty circuit condition by status LEDs

SKU: YE3826A

Description

FEATURES

  • 12 channel and 19” case

 

  • Selectable supply currents: 4mA, 10mA

 

  • Supply to and amplify of ICP transducers.

 

  • 10 times signal amplification

 

  • Wide frequency bandwidth

 

  • Operating status indications

 

  • BNC output or 25 way D-connector output

 

SUPPLIED WITH

Input cable 12 2-meter STYV-2 cables fitting with BNC socket at one end and L2 plug at other end.
Output cable 12 2-meter coax cable with BNC sockets
Power supply cable AC power supply cable (0.3A)

 

PERFORMANCE

Input channels 12
Input voltage range -10V to 10v peak (ICP transducers output)
Supply voltage to transducer 24V DC
Supply current to transducer 4mA or 10mA (default to 10mA)
Output voltage -10V to +10V peak
Output current 5mA
Gains ×1, ×10
Accuracy ≤±1.0%
DC offset ±10mV
Noise ≤1mV
Upper cutoff frequency 100kHz,
Lower cutoff frequency 0.3Hz
Power supplies AC 220V±10%,at 50Hz and 0.2A, DC 20 to 36 V/100mAV (recommend 24V)

 

PHYSICAL CHARACTERISTICS

Dimensions 430mm(W) × 44mm(H) × 240mm(D)
Weight 2kg
Electrical connection BNC plugs for input; BNC plugs and 25 way D socket for output

 

ENVIRIONMENT CHARACTERISTICS

Operating temperature 0°C to 40°C
Storage temperature -55°C to 85°C
Maximum humidity 95% RH

 

Download a PDF Download a PDF version of this document