Description
FEATURES
- Connection with standard cable
- Simple measurement system
SUPPLIED WITH
- STYV-1 cable, fitted with L5 connector (2metres)
PERFORMANCE
Sensitivity (20±5°C) |
50mV/ms-2 |
Measurement range |
100ms-2 |
Transverse sensitivity |
≤5% |
Frequency response |
see graph below |
Frequency range (10%) |
0.2Hz to 2.5kHz |
Resonant frequency |
8kHz |
Temperature response |
see graph below |
Output phase |
in phase with input |
ELECTRICAL CHARACTERISTICS
Supply voltage |
12V to 28V (DC) |
Operating current |
2mA to 10mA |
Maximum output (peak) |
5V |
Output impedance |
<100Ω |
Noise (1Hz to 20 kHz) |
<8×10-4ms-2 |
DC offset |
7±1V |
ENVIRONMENTAL CHARACTERISTICS
Temperature range |
-20°C to 120°C |
Shock limit |
10,000ms-2 |
Thermal transient sensitivity |
0.2ms-2/°C (0.3Hz) |
Magnetic sensitivity |
5.52ms-2/T |
Base strain sensitivity |
4×10-3ms-2/με |
PHYSICAL CHARACTERISTICS
Weight |
90g |
Case material |
stainless steel |
Mounting |
M5 thread |
Sensing element |
PZT-5 |
Sensing method |
plane shear |
Output connection |
L5 side connector |
Download a PDF version of this document